FU10s
Bomeitongbeauty
| Availability: | |
|---|---|
| Quantity: | |
Ultraformer Neck Tightening Face Firming Smas Lifting Best Face Machine for Wrinkles
| Probe specification | Number of shots | Frequency | Configuration |
| 1.5mm | 62000 shots (One shot fires 2points at the same time) | 10MHz | Optional |
| 2.0mm | 62000 shots (One shot fires 2 points at the same time) | 10MHz | Standard |
| 3.0mm | 62000 shots (One shot fires 2 points at the same time) | 7MHz | Standard |
| 4.5mm | 62000 shots (One shot fires 2 points at the same time) | 4MHz | Standard |
| 6.0mm | 62000 shots (One shot fires 4 points at the same time) | 4MHz | Optional |
| 8.0mm | 62000 shots (One shot fires 4 points at the same time) | 4MHz | Optional |
| 10.0mm | 62000 shots (One shot fires 4 points at the same time) | 4MHz | Optional |
| 13.0mm | 62000 shots (One shot fires 4 points at the same time) | 4MHz | Standard |
| 16.0mm | 62000 shots (One shot fires 4 points at the same time) | 4MHz | Optional |
| Ice HIFU VS Traditional Conventional HIFU | ||
| Product | Ice Hifu | Traditional HIFU |
| Cooling System | Water Cooling System, Cooling up to 1℃~5℃ | / |
| Pain | Cool feeling, painless and comfortable | Intense Pain |
| Safety | The circulating water of the cooler surrounds the HIFU probe to cool the probe to protect the epidermis and avoid redness,swelling and pain. | Burning and pain are relatively obvious , the skin is prone to burn risk, redness, pain and other side effects. |
| Wave Plate Sensor | Four/two wave plates, the work efficiency is increased by 2-4 times. One shot fires two or four energy points at the same time | A single wave-plate. Single row/multi-row: Only one point at a time can be fired gradually. |
| Treatment Time | About 20-30 minutes | About 60-90 minutes |
Ultraformer Neck Tightening Face Firming Smas Lifting Best Face Machine for Wrinkles
| Probe specification | Number of shots | Frequency | Configuration |
| 1.5mm | 62000 shots (One shot fires 2points at the same time) | 10MHz | Optional |
| 2.0mm | 62000 shots (One shot fires 2 points at the same time) | 10MHz | Standard |
| 3.0mm | 62000 shots (One shot fires 2 points at the same time) | 7MHz | Standard |
| 4.5mm | 62000 shots (One shot fires 2 points at the same time) | 4MHz | Standard |
| 6.0mm | 62000 shots (One shot fires 4 points at the same time) | 4MHz | Optional |
| 8.0mm | 62000 shots (One shot fires 4 points at the same time) | 4MHz | Optional |
| 10.0mm | 62000 shots (One shot fires 4 points at the same time) | 4MHz | Optional |
| 13.0mm | 62000 shots (One shot fires 4 points at the same time) | 4MHz | Standard |
| 16.0mm | 62000 shots (One shot fires 4 points at the same time) | 4MHz | Optional |
| Ice HIFU VS Traditional Conventional HIFU | ||
| Product | Ice Hifu | Traditional HIFU |
| Cooling System | Water Cooling System, Cooling up to 1℃~5℃ | / |
| Pain | Cool feeling, painless and comfortable | Intense Pain |
| Safety | The circulating water of the cooler surrounds the HIFU probe to cool the probe to protect the epidermis and avoid redness,swelling and pain. | Burning and pain are relatively obvious , the skin is prone to burn risk, redness, pain and other side effects. |
| Wave Plate Sensor | Four/two wave plates, the work efficiency is increased by 2-4 times. One shot fires two or four energy points at the same time | A single wave-plate. Single row/multi-row: Only one point at a time can be fired gradually. |
| Treatment Time | About 20-30 minutes | About 60-90 minutes |